Priority 2: AS BUILT PRINT DOES NOT MATCH WHAT"S IN THE FIELD FOR RISER.
Loading stormwater records…
Loading stormwater records…
STORMWATER FACILITY
3405 WHITE HORSE RD.
Greenville County · South Carolina
Condition describes the latest dated source assessment available, not a verified present-day assessment.
| Date | Record | Condition / result | Repairs & notes | Evidence |
|---|---|---|---|---|
| Jan 12, 2015 | InspectionPeriodic Inspection | Acceptable | Not recorded | Greenville County public stormwater BMP GIS |
| Jun 16, 2011 | InspectionRe-Inspection | Unacceptable | OUTLET STRUCTURE DOES NOT MATCH AS BUILTS. | Greenville County public stormwater BMP GIS |
| Apr 1, 2011 | InspectionInitial Inventory/Inspection | Unacceptable | Priority 2: AS BUILT PRINT DOES NOT MATCH WHAT"S IN THE FIELD FOR RISER. | Greenville County public stormwater BMP GIS |
Published inspection recommendations are shown with their dates. The database does not establish whether these repairs remain unresolved.
Priority 2: AS BUILT PRINT DOES NOT MATCH WHAT"S IN THE FIELD FOR RISER.
Recorded condition: Source score: 100
Review supporting evidence →Recorded condition: Acceptable
Review supporting evidence →Recorded condition: Unacceptable
Review supporting evidence →Recorded condition: Unacceptable · Repair recommendations recorded
Review supporting evidence →Published values appear beside the database value. Retrieval time records when evidence was collected; it is not an inspection or source-update date.
| Fact | Database value | Original source value |
|---|---|---|
| Bmp Id | MSR-610 | MSR-610 |
| Source Record Id | 1653 | 1653 |
| Legacy Asset Id | 610 | 610 |
| Parcel Id | 0242030303300 | 0242030303300 |
| Address | 3405 WHITE HORSE RD. | 3405 WHITE HORSE RD. |
| Source facility type | Dry Detention Pond | Dry Detention Pond |
| Site Name | SHEAD PROPERTIES LLC. {POND 3} | SHEAD PROPERTIES LLC. {POND 3} |
| Responsible party | SHEAD PROPERTIES LLC. | SHEAD PROPERTIES LLC. |
| Source owner category | Private | Private |
| Condition Date | 2025-03-14T19:03:36.000Z | 1741979016000 |
| Source condition score | 100 | 100 |
| Fact | Database value | Original source value |
|---|---|---|
| Bmp Id | MSR-610 | MSR-610 |
| Source Record Id | 439 | 439 |
| Legacy Asset Id | 610 | 610 |
| Source facility type | Dry Detention Pond | Dry Detention Pond |
| Fact | Database value | Original source value |
|---|---|---|
| Bmp Id | MSR-610 | MSR-610 |
| Source Record Id | 611 | 611 |
| Legacy Asset Id | 610 | 610 |
| Inspection date | 2011-04-01T08:17:55.000Z | 1301645875000 |
| Inspection Type | Initial Inventory/Inspection | Initial Inventory/Inspection |
| Overall condition | Unacceptable | Unacceptable |
| Priority 2 repair recommendations | AS BUILT PRINT DOES NOT MATCH WHAT"S IN THE FIELD FOR RISER. | AS BUILT PRINT DOES NOT MATCH WHAT"S IN THE FIELD FOR RISER. |
| Last Cleaned | 2011-04-01T08:18:12.000Z | 1301645892000 |
| Vegetation Condition | Yes | Yes |
| Sediment Condition | Yes | Yes |
| Trash Condition | Yes | Yes |
| Outlet Condition | Yes | Yes |
| Fact | Database value | Original source value |
|---|---|---|
| Bmp Id | MSR-610 | MSR-610 |
| Source Record Id | 1392 | 1392 |
| Legacy Asset Id | 610 | 610 |
| Inspection date | 2011-06-16T10:34:32.000Z | 1308220472000 |
| Inspection Type | Re-Inspection | Re-Inspection |
| Overall condition | Unacceptable | Unacceptable |
| Inspection notes | OUTLET STRUCTURE DOES NOT MATCH AS BUILTS. | OUTLET STRUCTURE DOES NOT MATCH AS BUILTS. |
| Last Cleaned | 2011-06-16T10:34:49.000Z | 1308220489000 |
| Vegetation Condition | Yes | Yes |
| Sediment Condition | Yes | Yes |
| Trash Condition | Yes | Yes |
| Outlet Condition | Yes | Yes |
| Fact | Database value | Original source value |
|---|---|---|
| Bmp Id | MSR-610 | MSR-610 |
| Source Record Id | 5022 | 5022 |
| Legacy Asset Id | 610 | 610 |
| Inspection date | 2015-01-12T14:52:44.000Z | 1421074364000 |
| Inspection Type | Periodic Inspection | Periodic Inspection |
| Overall condition | Acceptable | Acceptable |
| Vegetation Condition | Yes | Yes |
| Sediment Condition | Yes | Yes |
| Trash Condition | Yes | Yes |
| Outlet Condition | Yes | Yes |
| Fact | Database value | Original source value |
|---|---|---|
| Bmp Id | MSR-610 | MSR-610 |
| Source Record Id | 611 | 611 |
| Legacy Asset Id | 610 | 610 |
| Inspection date | 2011-04-01T08:17:55.000Z | 1301645875000 |
| Inspection Type | Initial Inventory/Inspection | Initial Inventory/Inspection |
| Overall condition | Unacceptable | Unacceptable |
| Priority 2 repair recommendations | AS BUILT PRINT DOES NOT MATCH WHAT"S IN THE FIELD FOR RISER. | AS BUILT PRINT DOES NOT MATCH WHAT"S IN THE FIELD FOR RISER. |
| Last Cleaned | 2011-04-01T08:18:12.000Z | 1301645892000 |
| Vegetation Condition | Yes | Yes |
| Sediment Condition | Yes | Yes |
| Trash Condition | Yes | Yes |
| Outlet Condition | Yes | Yes |
| Fact | Database value | Original source value |
|---|---|---|
| Bmp Id | MSR-610 | MSR-610 |
| Source Record Id | 1392 | 1392 |
| Legacy Asset Id | 610 | 610 |
| Inspection date | 2011-06-16T10:34:32.000Z | 1308220472000 |
| Inspection Type | Re-Inspection | Re-Inspection |
| Overall condition | Unacceptable | Unacceptable |
| Inspection notes | OUTLET STRUCTURE DOES NOT MATCH AS BUILTS. | OUTLET STRUCTURE DOES NOT MATCH AS BUILTS. |
| Last Cleaned | 2011-06-16T10:34:49.000Z | 1308220489000 |
| Vegetation Condition | Yes | Yes |
| Sediment Condition | Yes | Yes |
| Trash Condition | Yes | Yes |
| Outlet Condition | Yes | Yes |
| Fact | Database value | Original source value |
|---|---|---|
| Bmp Id | MSR-610 | MSR-610 |
| Source Record Id | 5022 | 5022 |
| Legacy Asset Id | 610 | 610 |
| Inspection date | 2015-01-12T14:52:44.000Z | 1421074364000 |
| Inspection Type | Periodic Inspection | Periodic Inspection |
| Overall condition | Acceptable | Acceptable |
| Vegetation Condition | Yes | Yes |
| Sediment Condition | Yes | Yes |
| Trash Condition | Yes | Yes |
| Outlet Condition | Yes | Yes |